Prevention of Angular Buried Pipe Failures Under Shear Static Loads Using Granular Waste Tires

dc.contributor.advisor Ecemiş, Nurhan
dc.contributor.author Albayrak, Burak
dc.contributor.other 03.03. Department of Civil Engineering
dc.contributor.other 03. Faculty of Engineering
dc.contributor.other 01. Izmir Institute of Technology
dc.date.accessioned 2025-06-26T20:21:45Z
dc.date.available 2025-06-26T20:21:45Z
dc.date.issued 2025
dc.description Thesis (Master)--Izmir Institute of Technology, Civil Engineering, Izmir, 2025 en_US
dc.description Includes bibliographical references (leaves. 56-59) en_US
dc.description Text in English; Abstract: Turkish and English en_US
dc.description.abstract Doğalgaz boruları, ulusal ekonomilerde önemli bir rol oynamaktadır, bu nedenle zarar görmemeleri ve işlevsiz hale gelmemeleri hayati önem taşımaktadır. Bu çalışma, gömülü boru hatlarının statik yükler karşısında granular atık lastikler kullanılarak korunmasını ele almaktadır. Gömülü borunun davranışı, etrafına 10-15 mm çapında granular atık lastikler serilerek ve boruya dışarıdan uygulanan kuvvetlere karşı gösterdiği tepki incelenerek araştırılmıştır. Ayrıca, karşılaştırma yapmak amacıyla bu deneyler boru etrafına siltli kum serilerek tekrarlanmıştır. Deneylerde ayrıca laminar kutunun kayma bölümü ile parçalı boru ek yeri arasındaki mesafe incelenmiş ve kademeli olarak artırılmıştır. Laminar kutuda yapılan deneylerde, dikey konumlandırılmış PE80 doğalgaz borusu için dolgu malzemesi olarak granüler atık lastik ve siltli kum kullanıldı; kuvvetler, gerinim ölçerler ve yük hücresi ile ölçüldü. Eğimli bir doğalgaz borusu, üzerindeki örtü yükü ve derinlikle artan yan basınca maruz kalırken, dikey bir boru yalnızca derinlikle artan yan basınca maruz kalır. Yatay bir boruya uygulanan dış kuvveti simüle etmek için, üçgen yayılı bir yük uygulanır ve bu, hem dikey hem de eğimli borular için tutarlı koşullar sağlar. Bu yüzden deneyde kullanılan boru dikey olarak yerleştirilmiş ve dikey haldeki boruya gelen kuvvetler borunun yatay hali için de sembolize edilerek bir denklik verilmiştir. Sonuç olarak, dolgu malzemesi olarak granüler atık lastik kullanımı, boru üzerine dışarıdan uygulanan yükleri siltli kuma kıyasla daha etkili bir şekilde sönümlemiştir. Boşluk oranı farklılığından dolayı dolgu malzemesi siltli kum olduğunda, boru üzerindeki yük çok kısa bir sürede ve hareketli bloğun minimum yer değiştirmesiyle etkisini göstermeye başlamıştır.
dc.description.abstract Pipelines play a crucial role in national economies, and therefore, it is essential that they do not get damaged and become non-operational. This study is about the protection of buried pipelines against static loads using granular waste tires. The behavior of the buried pipe was investigated by placing granular waste tires with a diameter of 10-15 mm around it and examining its response to externally applied forces. Additionally, for comparison purposes, these experiments were repeated by placing silty sand around the pipe. The experiments also examined the distance between the laminar box's shear section and the segmented pipe joint, increasing it incrementally. Experiments in the laminar box used granular waste tire and silty sand as backfill for a vertical PE80 gas pipe, with strain gauges and a load cell measuring applied forces. An inclined natural gas pipe is subjected to both the overburden load and lateral pressure increasing with depth, whereas a vertical pipe experiences only the lateral pressure increasing with depth. To simulate the external force applied to a horizontal pipe, a triangularly distributed load is applied, ensuring consistent conditions for both vertical and inclined pipes. Therefore, the pipe used in the experiment was positioned vertically, and the forces acting on the vertically oriented pipe were represented to establish an equivalence for the horizontal configuration of the pipe. As a result, the use of granular waste tires as a backfill material has dampened the externally applied loads on the pipe more effectively compared to silty sand. When the backfill material is silty sand, the load on the pipe begins to take effect within a very short time and with minimal displacement of the movable block due to differences in void ratio. en_US
dc.format.extent xv, 85 leaves en_US
dc.identifier.uri https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=htlyhJG97gjBTPjAeWRhPrc8GNyLC2fgg1SEVTzPdmKZJhsDP-xnSNjf3gCtfCGc
dc.identifier.uri https://hdl.handle.net/11147/15712
dc.language.iso en
dc.publisher 01. Izmir Institute of Technology en_US
dc.subject Natural gas pipelines, Design and construction en_US
dc.subject Pipelines, Design and construction en_US
dc.subject Pipelines, Maintenance and repair en_US
dc.title Prevention of Angular Buried Pipe Failures Under Shear Static Loads Using Granular Waste Tires en_US
dc.title.alternative Açılı Gömülü Borunun Granüler Atık Lastik Kullanılarak Statik Kesme Yükleri Altında Deformasyonlarının Önlenmesi
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.id 0009-0005-3189-9367
gdc.author.institutional Ecemiş, Nurhan
gdc.description.department Thesis (Master)--İzmir Institute of Technology, Civil Engineering en_US
gdc.description.endpage 100
gdc.description.publicationcategory Tez
gdc.identifier.yoktezid 936551
relation.isAuthorOfPublication 9dfb1ea6-67a1-45d6-b10d-f66015b65b0c
relation.isAuthorOfPublication.latestForDiscovery 9dfb1ea6-67a1-45d6-b10d-f66015b65b0c
relation.isOrgUnitOfPublication 9af2b05f-28ac-4020-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4004-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4003-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4020-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
15712.pdf
Size:
4.98 MB
Format:
Adobe Portable Document Format
Description:
Master Thesis