Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/10211
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGençer, Fundatr
dc.contributor.authorTuran, Minetr
dc.contributor.authorAktaş, Engintr
dc.date.accessioned2021-01-24T18:32:59Z-
dc.date.available2021-01-24T18:32:59Z-
dc.date.issued2020-
dc.identifier.issn2352-409X-
dc.identifier.urihttps://doi.org/10.1016/j.jasrep.2020.102663-
dc.identifier.urihttps://hdl.handle.net/10211-
dc.description.abstractUnderstanding how the original characteristics contribute to the structural behaviour of antique structures should be the initial stage of planning for conservation work. This study aims to identify the structural behaviour of dry masonry towers under lateral loadings, so that the decision-making process when determining their restoration can be adequately supported. Dry masonry towers in ancient Caria, Pamphylia, and Cilicia Regions are examined. Each of these three areas have very different seismic characteristics. A hypothetical testing process was designed by combining different characteristics from each of the towers. As a result, the characteristics affecting the structural resistance were determined as; the staggering ratio, the stone depth, the ratio between block length and height, the proportional relationship between height and length, the area, number and position of openings, and the distribution of header stones. These characteristics all interact together to determine the failure mechanism; so, understanding this interaction is critical when considering conservation. © 2020 Elsevier Ltden_US
dc.description.sponsorshipThis study has been supported by the Scientific Research Project Department of İzmir Institute of Technology, Turkey within the scope of the project, numbered 2016G_IYTE83.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofJournal of Archaeological Science: Reportsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAncient towersen_US
dc.subjectConservationen_US
dc.subjectDry masonryen_US
dc.subjectFailure mechanismen_US
dc.subjectResistanceen_US
dc.titleStructural vulnerability of ancient dry masonry towers under lateral loadingen_US
dc.typeArticleen_US
dc.institutionauthorTuran, Minetr
dc.institutionauthorAktaş, Engintr
dc.departmentİzmir Institute of Technology. Conservation and Restoration of Cultural Heritageen_US
dc.departmentİzmir Institute of Technology. Civil Engineeringen_US
dc.identifier.volume34en_US
dc.identifier.wosWOS:000601394400001en_US
dc.identifier.scopus2-s2.0-85096099669en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr
dc.identifier.doi10.1016/j.jasrep.2020.102663-
dc.relation.doi10.1016/j.jasrep.2020.102663en_US
dc.coverage.doi10.1016/j.jasrep.2020.102663en_US
dc.identifier.scopusqualityQ1-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.languageiso639-1en-
item.fulltextWith Fulltext-
crisitem.author.dept02.01. Department of Conservation and Restoration of Cultural Heritage-
crisitem.author.dept03.03. Department of Civil Engineering-
Appears in Collections:Civil Engineering / İnşaat Mühendisliği
Conservation and Restoration of Cultural Heritage / Kültür Varlıklarını Koruma ve Onarım
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
1-s2.0-S2352409X20304545-main.pdf29.19 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

2
checked on Mar 30, 2024

Page view(s)

184
checked on Apr 22, 2024

Download(s)

22
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.