Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/10225
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKöse, Büşra-
dc.contributor.authorKazanasmaz, Zehra Tuğçe-
dc.date.accessioned2021-01-24T18:33:05Z-
dc.date.available2021-01-24T18:33:05Z-
dc.date.issued2020-
dc.identifier.issn0236-2945-
dc.identifier.urihttps://doi.org/10.33383/2019-038-
dc.identifier.urihttps://hdl.handle.net/11147/10225-
dc.description.abstractThis study examines the performance of attached prismatic panels, which have shading capability, in a side-lit deep plan room to find out the least possible WWR value in relation to room depth satisfying the required daylight availability. The methodology is based on simulating a base model in Relux and testing it with alternative models composed of incrementally defined WWR and room depth values. In accordance with minimum IES requirements, the most satisfying sDA value was found to be 48.54 % in a room of 12 m depth with 67 % WWR. An sDA of 51.59 % and 59.26 % was achieved in a room of 9m depth with 43 % WWR and 6m depth with 30 % WWR, respectively. The least ASE values were obtained with the least WWR alternative of 30 % in all room depths. This study presents a new approach with the consideration of innovative daylight redirecting systems to propose revisions for the requirements mentioned in standards about daylight in buildings but based on conventional fenestration systems. © 2020, LLC Editorial of Journal ""Light Technik"". All rights reserved.en_US
dc.language.isoenen_US
dc.publisherZnack Publishing Houseen_US
dc.relation.ispartofLight and Engineeringen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDaylighten_US
dc.subjectPrismatic panelsen_US
dc.subjectRoom depthen_US
dc.subjectWindowsen_US
dc.titleApplicability of a prismatic panel to optimize window size and depth of a south-facing room for a better daylight performanceen_US
dc.typeArticleen_US
dc.institutionauthorKöşe, Büşra-
dc.institutionauthorKazanasmaz, Zehra Tuğçe-
dc.departmentİzmir Institute of Technology. Architectureen_US
dc.identifier.volume28en_US
dc.identifier.issue4en_US
dc.identifier.startpage63en_US
dc.identifier.endpage67en_US
dc.identifier.wosWOS:000620643000004en_US
dc.identifier.scopus2-s2.0-85095443291en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.33383/2019-038-
dc.relation.doi10.33383/2019-038en_US
dc.coverage.doi10.33383/2019-038en_US
dc.identifier.wosqualityQ4-
dc.identifier.scopusqualityQ3-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairetypeArticle-
crisitem.author.dept02.02. Department of Architecture-
Appears in Collections:Architecture / Mimarlık
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
2019_kose_kmaz_LE_rev.pdf603.95 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

5
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

5
checked on Mar 27, 2024

Page view(s)

716
checked on Apr 15, 2024

Download(s)

392
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.