dc.description.abstractThis paper shows that the peak temperature of a non-uniformly heated region can be decreased by embedding high-conductivity tree-shaped inserts which is in contact with a heat sink from its stem. The volume fraction of the high-conductivity material is fixed, and so is the volume of the solid region. The length scale of the solid domain is L. Inside there is a cube-shaped region with length scale of 0.1L and heat production 100 times greater than the rest of the domain. The location of this hot spot was varied to uncover how its location affects the peak temperature and the design of inverted fins, i.e. highconductivity tree-shaped inserts. The volume fraction of the high-conductivity tree was varied for number of bifurcation levels of 0, 1 and 2. This showed that increasing the number of the bifurcation levels decreases the peak temperature when the volume fraction decreases. The optimal diameter ratios and optimal bifurcation angles at the each junction level are also documented. Y-shaped trees promise smaller peak temperatures than T-shaped trees. The location of the vascular tree in the z direction also affects the peak temperature when the heat generation is non-uniform. In addition, the peak temperature is minimum when z = 0.65L even though the hot spot is located on z = 0.75L.en_US
dc.description.sponsorshipThis work was supported by the Republic of Turkey. Almogbel and Bejan's [19] data was used in this paper for the validation process. The author wishes to thank him for his contribution to the subject of conductive cooling.en_US
dc.language.isoenen_US
dc.publisherYıldız Teknik Üniversitesien_US
dc.relation.ispartofJournal of Thermal Engineeringen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectConstructalen_US
dc.subjectInverted finsen_US
dc.subjectVascularen_US
dc.subjectNon-uniform heatingen_US
dc.subjectConductive coolingen_US
dc.subjectTree-shapeden_US
dc.titleInverted fins for cooling of a non-uniformly heated domainen_US
dc.typeArticleen_US
dc.institutionauthorÇetkin, Erdaltr
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.volume1en_US
dc.identifier.issue1en_US
dc.identifier.startpage1en_US
dc.identifier.endpage9en_US
dc.identifier.wosWOS:000434614600001en_US
dc.identifier.scopus2-s2.0-84936950899en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr
dc.identifier.doi10.18186/jte.12488-
dc.relation.doi10.18186/jte.12488en_US
dc.coverage.doi10.18186/jte.12488en_US
dc.identifier.scopusquality--
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.languageiso639-1en-
item.fulltextWith Fulltext-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
Inverted_fins.pdf2.09 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

11
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

12
checked on Mar 23, 2024

Page view(s)

802
checked on Apr 22, 2024

Download(s)

18
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.