Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/11254
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTorabnia, Shams-
dc.contributor.authorMihçin, Şenay-
dc.contributor.authorLazoğlu, İsmail-
dc.date.accessioned2021-11-06T09:27:12Z-
dc.date.available2021-11-06T09:27:12Z-
dc.date.issued2021-
dc.identifier.isbn9781665419147-
dc.identifier.urihttp://doi.org/10.1109/MeMeA52024.2021.9478689-
dc.identifier.urihttps://hdl.handle.net/11147/11254-
dc.description2021 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2021 -- 23 June 2021 through 25 June 2021en_US
dc.description.abstractThe simulation of wear, between the components of artificial hip joint implants, is a complicated problem that does not have a robust analytical answer yet. Many studies have been conducted to predict the wear between the femur head and the acetabular cup, as the debris generated due to the wear might produce adverse effects after the surgery. Hip joint simulators provide a means to quantify the amount of wear in preclinical settings, as an in vitro method. However, this brings some other challenges in terms of bio-fidelity. The simulators use force and range of motion data as input and provide wear information as an output. For this reason, it is important to be able to simulate the realistic conditions, by the proper transmission of force and position controlling of the components. Many studies performed on wear simulators but none of them worked on the machine parameters such as power consumption and sensitivity to external inputs in detail. In this study, we perform a sensitivity analysis of the factors affecting the forces acting on the femur head. In silico simulations were performed by changing the values of acting force, friction coefficient, and radius of femur head to understand the effects of each parameter on the frictional moment of the joint. These analyses demonstrate the importance of using correct parameters while designing simulators, which accept flexible boundary conditions. The architecture of the hip simulator was also investigated for the first time. The results are expected to pave the way for improving the bio-fidelity of the simulators in the field of biomechanics. © 2021 IEEE.en_US
dc.description.sponsorshipThis research is a part of a collaboration between the Manufacturing and Automation Research Center (MARC) at Koç University and the Izmir Institute of Technology. This project was funded by Tubitak 2232 international fellowship, for Outstanding researchers, under project number 118C188 'New Generation Implants for All'.en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartof2021 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2021 - Conference Proceedingsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIn vitroen_US
dc.subjectParametric designen_US
dc.subjectSimulatoren_US
dc.subjectTotal hip replacementen_US
dc.titleParametric analysis for the design of hip joint replacement simulatorsen_US
dc.typeConference Objecten_US
dc.institutionauthorMihçin, Şenay-
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.wosWOS:000847048100039en_US
dc.identifier.scopus2-s2.0-85114132362en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1109/MeMeA52024.2021.9478689-
dc.authorscopusid55566426900-
dc.authorscopusid57185637300-
dc.authorscopusid6602539044-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeConference Object-
item.languageiso639-1en-
item.fulltextWith Fulltext-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
Parametric_analysis.pdf2.85 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

1
checked on Mar 30, 2024

Page view(s)

116
checked on Apr 22, 2024

Download(s)

160
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.