Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/12402
Title: A comparative study of HPLC and UV spectrophotometric methods for oseltamivir quantification in pharmaceutical formulations
Authors: Güngör, Serdar
Bulduk, Ibrahim
Aydın, Beyza Sultan
İlikçi Sağkan, Rahşan
Keywords: Oseltamivir
COVID-19
Ultraviolet
LC methods
Publisher: Akademiai Kiado
Abstract: Oseltamivir is an antiviral drug and is used in the treatment of all influenza viruses. It is the most effective antiviral option against all influenza viruses that can infect humans. UV and LC methods have been developed and validated according to ICH guidelines for various parameters like selectivity, linearity, accuracy, precision, LOD and LOQ, robustness for the quantitative determination of oseltamivir in pharmaceutical formulations. LC method has been performed using reverse phase technique on a C-18 column with a mobile phase consisting of 20 mM potassium dihydrogen phosphate solution and acetonitrile (60:40, v/v) at 25 8C. The mobile phase flow rate was 1.2 mL min-1. For the determination of oseltamivir, UV spectrum has been recorded between 200 and 800 nm using methanol as solvent and the wavelength of 215 nm has been selected. Both methods have demonstrated good linearity, precision and recovery. No spectral and chromatographic interferences from the capsule excipients were found in UV and LC methods. In both methods, correlation coefficients were greater than 0.999 within a concentration range of 10???60 mg mL-1 using UV and LC. Intra-day and inter-day precision with low relative standard deviation values were observed. The accuracy of these methods was within the range 99.85???100.17% for LC and from 99.26 to 100.70% for UV. Therefore UV and LC methods gave the most reliable outcomes for the determination of oseltamivir in pharmaceutical formulation.
URI: http://dx.doi.org/10.1556/1326.2021.00925
https://hdl.handle.net/11147/12402
Appears in Collections:Molecular Biology and Genetics / Moleküler Biyoloji ve Genetik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
2083-5736-article-p258.pdfArticle1.25 MBAdobe PDFView/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

1
checked on Mar 30, 2024

Page view(s)

9,924
checked on Apr 22, 2024

Download(s)

222
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.