Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/14170
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Biesuz, M. | - |
dc.contributor.author | Karacasulu, L. | - |
dc.contributor.author | Vakifahmetoglu, C. | - |
dc.contributor.author | Sglavo, V.M. | - |
dc.date.accessioned | 2024-01-06T07:22:30Z | - |
dc.date.available | 2024-01-06T07:22:30Z | - |
dc.date.issued | 2023 | - |
dc.identifier.issn | 0955-2219 | - |
dc.identifier.uri | https://doi.org/10.1016/j.jeurceramsoc.2023.11.061 | - |
dc.identifier.uri | https://hdl.handle.net/11147/14170 | - |
dc.description.abstract | Temperature measurement upon ultrafast high-temperature sintering (UHS) is a crucial task. Herein, we provide some arguments posing concerns about the use of metal-shielded thermocouples as temperature probes in UHS. The discussion is based on literature data and on some ad hoc experiments. In detail, we show at least two cases in the literature where the use of a shielded thermocouple causes a substantial underestimation of the UHS temperature. The argumentation is based on comparing the thermocouples read and the observed phase and microstructural evolution. Moreover, by means of a simple experimental design, we show that a metal shield on the thermocouple tip can substantially reduce the measured temperature. Since the metal shield is orders of magnitude more thermally conductive than the graphite felt used as heating element in UHS, it efficiently removes heat from the thermocouple tip region. As such, data acquired from shielded thermocouples must be treated with care. © 2023 Elsevier Ltd | en_US |
dc.description.sponsorship | European Commission, EC: 2022KWSRSA; Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK; Ministero dello Sviluppo Economico, MiSE: F/310085/01/X56 | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ltd | en_US |
dc.relation.ispartof | Journal of the European Ceramic Society | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Sintering | en_US |
dc.subject | Thermocouples | en_US |
dc.subject | UHS | en_US |
dc.subject | Ultrafast high-temperature sintering | en_US |
dc.subject | Temperature measurement | en_US |
dc.subject | Thermocouples | en_US |
dc.subject | High-temperature sintering | en_US |
dc.subject | Literature data | en_US |
dc.subject | Simple++ | en_US |
dc.subject | Sintering temperatures | en_US |
dc.subject | Temperature probes | en_US |
dc.subject | Ultra-fast | en_US |
dc.subject | Ultrafast high-temperature sintering | en_US |
dc.subject | Sintering | en_US |
dc.title | On the temperature measurement during ultrafast high-temperature sintering (UHS): Shall we trust metal-shielded thermocouples? | en_US |
dc.type | Article | en_US |
dc.institutionauthor | … | - |
dc.department | İzmir Institute of Technology | en_US |
dc.identifier.scopus | 2-s2.0-85179476868 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.jeurceramsoc.2023.11.061 | - |
dc.authorscopusid | 56660576700 | - |
dc.authorscopusid | 57190733676 | - |
dc.authorscopusid | 24072592200 | - |
dc.authorscopusid | 7003444569 | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 03.09. Department of Materials Science and Engineering | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.