Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/14286
Title: Measuring the performance of an artificial intelligence-based robot that classifies blood tubes and performs quality control in terms of preanalytical errors: A preliminary study
Authors: Sisman, Ali Riza
Basok, Banu Isbilen
Kara, Inanc
Colak, Ayfer
Bilge, Ugur
Demirci, Ferhat
Basoglu, Nuri
Keywords: preanalytical phase
tube sorting
quality control
artificial intelligence
Publisher: Oxford Univ Press inc
Abstract: Objectives Artificial intelligence-based robotic systems are increasingly used in medical laboratories. This study aimed to test the performance of KANKA (Labenko), a stand-alone, artificial intelligence-based robot that performs sorting and preanalytical quality control of blood tubes.Methods KANKA is designed to perform preanalytical quality control with respect to error control and preanalytical sorting of blood tubes. To detect sorting errors and preanalytical inappropriateness within the routine work of the laboratory, a total of 1000 blood tubes were presented to the KANKA robot in 7 scenarios. These scenarios encompassed various days and runs, with 5 repetitions each, resulting in a total of 5000 instances of sorting and detection of preanalytical errors. As the gold standard, 2 experts working in the same laboratory identified and recorded the correct sorting and preanalytical errors. The success rate of KANKA was calculated for both the accurate tubes and those tubes with inappropriate identification.Results KANKA achieved an overall accuracy rate of 99.98% and 100% in detecting tubes with preanalytical errors. It was found that KANKA can perform the control and sorting of 311 blood tubes per hour in terms of preanalytical errors.Conclusions KANKA categorizes and records problem-free tubes according to laboratory subunits while identifying and classifying tubes with preanalytical inappropriateness into the correct error sections. As a blood acceptance and tube sorting system, KANKA has the potential to save labor and enhance the quality of the preanalytical process.
Description: Demirci, Ferhat/0000-0002-5999-3399; Bilge, Ugur/0000-0002-5186-1092; Basok, Banu Isbilen/0000-0002-1483-997X
URI: https://doi.org/10.1093/ajcp/aqad179
https://hdl.handle.net/11147/14286
ISSN: 0002-9173
1943-7722
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

WEB OF SCIENCETM
Citations

1
checked on Apr 27, 2024

Page view(s)

34
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.