Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/14579
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCoskun,T.-
dc.contributor.authorArsan,Z.D.-
dc.contributor.authorAkkurt,G.G.-
dc.date.accessioned2024-06-19T14:29:43Z-
dc.date.available2024-06-19T14:29:43Z-
dc.date.issued2024-
dc.identifier.issn2352-7102-
dc.identifier.urihttps://doi.org/10.1016/j.jobe.2024.109890-
dc.identifier.urihttps://hdl.handle.net/11147/14579-
dc.description.abstractStructural retrofitting in buildings may result in changes in the indoor microclimate. Chemical, mechanical and biological deterioration can be seen in the cultural properties as a consequence of substrates and inappropriate microclimatic conditions such as high indoor temperature, relative humidity and fluctuations of them. The primary aim of the study is to evaluate the effect of the structural retrofitting, that the building underwent, on the chemical degradation risk of the library collection based on two different ventilation scenarios. One is natural ventilation which is an existing situation since the building is free-floating. The other one implementing a mechanical ventilation system into the building. To be able to compare the microclimate that affects the library collection pre- and post-retrofitting, two models are developed in DesginBuilder and simulated for both scenarios. According to the results of the post-retrofitting model, mechanical ventilation reduced the risk of chemical degradation by 38 %, while natural ventilation did not cause any effect. Natural ventilation gives a similar output in the pre-retrofitting model as in the post-retrofitting model. Mechanical ventilation in the pre-retrofitting model achieves a 33 % reduction in chemical degradation risk. Structural retrofitting only achieves a 1 % reduction in the chemical risk level for both ventilation scenarios. Thus, its effect on the indoor microclimate is insignificant. This study shows that creating simulation models effectively assesses potential risks pre-post-structural retrofitting or any retrofitting in historical buildings. Simulations reveal that mechanical ventilation is a better choice for decreasing chemical degradation risks for the library. © 2024 Elsevier Ltden_US
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.relation.ispartofJournal of Building Engineeringen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDegradation risksen_US
dc.subjectDesignBuilderen_US
dc.subjectHistoric libraryen_US
dc.subjectStructural retrofittingen_US
dc.subjectTire Necip Pasa Libraryen_US
dc.subjectVentilation scenariosen_US
dc.titleThe effect of structural retrofitting and ventilation scenarios on the indoor microclimate of a historical library: The Necip Pasa Library, Turkiyeen_US
dc.typeArticleen_US
dc.departmentIzmir Institute of Technologyen_US
dc.identifier.volume93en_US
dc.identifier.scopus2-s2.0-85195451727-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.jobe.2024.109890-
dc.authorscopusid57193159493-
dc.authorscopusid57215024565-
dc.authorscopusid56010236400-
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.grantfulltextnone-
item.openairetypeArticle-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

18
checked on Jul 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.