Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/2205
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAkram, Rizwan-
dc.contributor.authorFardmanesh, Mehdi-
dc.contributor.authorSchubert, Juergen-
dc.contributor.authorZander, Willi-
dc.contributor.authorBanzet, Marko-
dc.contributor.authorLomparski, Dieter-
dc.contributor.authorSchmidt, Miak-
dc.contributor.authorKrause, H. J.-
dc.date.accessioned2016-10-11T07:57:25Z
dc.date.available2016-10-11T07:57:25Z
dc.date.issued2006-08
dc.identifier.citationAkram, R., Fardmanesh, M., Schubert, J., Zander, W., Banzet, M., Lomparski, D., Schmidt, M., and Krause, H. J. (2006). Signal enhancement techniques for rf SQUID based magnetic imaging systems, Superconductor Science and Technology, 19(8), 821-824. doi:10.1088/0953-2048/19/8/023en_US
dc.identifier.issn0953-2048
dc.identifier.issn0953-2048-
dc.identifier.urihttp://doi.org/10.1088/0953-2048/19/8/023
dc.identifier.urihttp://hdl.handle.net/11147/2205
dc.description.abstractWe have investigated the rf SQUID (radio-frequency superconducting quantum interference device) and its coupling to tank circuit configurations to achieve an optimal front-end assembly for sensitive and high spatial resolution magnetic imaging systems. The investigation of the YBCO rf SQUID coupling to the conventional LC tank circuits revealed that coupling from the back of the SQUID substrate enhances the SQUID signal while facilitating the front-end assembly configuration. The optimal thickness of the substrate material between the SQUID and the tank circuit is 0.4 mm for LaAlO3 resulting in an increase of the SQUID flux-voltage transfer function signal, Vspp, of 1.5 times, and 0.5 mm for SrTiO3 with an increase of V spp of 1.62 times compared to that for direct face to face couplings. For rf coupling with a coplanar resonator, it has been found that the best configuration, in which a resonator is sandwiched between the SQUID substrate and the resonator substrate, provides a Vspp about 3.4 times higher than that for the worse case where the resonator and the SQUID are coupled back to back. The use of a resonator leads to a limitation of the achievable spatial resolution due to its flux focusing characteristics. This resulted in a favouring of the use of the conventional tank circuits when considering the desired high spatial resolution. The effect of the YBCO flip chip magnetic shielding of the SQUIDs in the back-coupling with the LC tank circuit configuration has also been investigated, with a view to reducing the SQUID effective area to increase the spatial resolution and also for studying the effect of the coupling of various kinds of transformers to the SQUIDs. It is revealed that there is no very considerable change in the flux-voltage transfer function signal level with respect to the effective shield area, while the lowest working temperature of the SQUIDs was slightly shifted higher by a couple of degrees, depending on the shield area.en_US
dc.language.isoenen_US
dc.publisherIOP Publishing Ltd.en_US
dc.relation.ispartofSuperconductor Science and Technologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSQUIDen_US
dc.subjectBack couplingen_US
dc.subjectCircuit configurationen_US
dc.subjectVoltage transfer functionsen_US
dc.subjectCoplanar resonatorsen_US
dc.titleSignal enhancement techniques for rf SQUID based magnetic imaging systemsen_US
dc.typeArticleen_US
dc.institutionauthorDemir, Durmuş Ali-
dc.departmentİzmir Institute of Technology. Physicsen_US
dc.identifier.volume19en_US
dc.identifier.issue8en_US
dc.identifier.startpage821en_US
dc.identifier.endpage824en_US
dc.identifier.wosWOS:000239025600027en_US
dc.identifier.scopus2-s2.0-33749057900en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1088/0953-2048/19/8/023-
dc.relation.doi10.1088/0953-2048/19/8/023en_US
dc.coverage.doi10.1088/0953-2048/19/8/023en_US
dc.identifier.wosqualityQ2-
dc.identifier.scopusqualityQ1-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.grantfulltextopen-
Appears in Collections:Physics / Fizik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
2205.pdfMakale625.54 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Mar 22, 2024

WEB OF SCIENCETM
Citations

3
checked on Mar 27, 2024

Page view(s)

80
checked on Mar 25, 2024

Download(s)

218
checked on Mar 25, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.