Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/2607
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDemir, Durmuş Ali-
dc.contributor.authorCMS Collaboration-
dc.date.accessioned2016-12-12T13:22:49Z-
dc.date.available2016-12-12T13:22:49Z-
dc.date.issued2010-
dc.identifier.citationChatrchyan, S., Khachatryan, V., Sirunyan, A. M., Adam. W., Arnold, B., ...CMS Collaboration (2010). Aligning the CMS muon chambers with the muon alignment system during an extended cosmic ray run. Journal of Instrumentation, 5(3). doi:10.1088/1748-0221/5/03/T03019en_US
dc.identifier.issn1748-0221-
dc.identifier.urihttp://doi.org/10.1088/1748-0221/5/03/T03019-
dc.identifier.urihttp://hdl.handle.net/11147/2607-
dc.description.abstractThe alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.en_US
dc.description.sponsorshipCERN and other CMS Institutes; TÜBİTAK and TAEKen_US
dc.language.isoenen_US
dc.publisherIOP Publishing Ltd.en_US
dc.relation.ispartofJournal of Instrumentationen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMuon spectrometersen_US
dc.subjectLarge detector systemsen_US
dc.subjectLarge Hadron Collider (LHC)en_US
dc.subjectCompact Muon Solenoiden_US
dc.subjectCosmic Run At Four Tesla (CRAFT)en_US
dc.titleAligning the CMS muon chambers with the muon alignment system during an extended cosmic ray runen_US
dc.typeArticleen_US
dc.authoridTR1918en_US
dc.institutionauthorDemir, Durmuş Ali-
dc.departmentİzmir Institute of Technology. Physicsen_US
dc.identifier.volume5en_US
dc.identifier.issue3en_US
dc.identifier.wosWOS:000280524100014en_US
dc.identifier.scopus2-s2.0-79953272770en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1088/1748-0221/5/03/T03019-
dc.relation.doi10.1088/1748-0221/5/03/T03019en_US
dc.coverage.doi10.1088/1748-0221/5/03/T03019en_US
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.languageiso639-1en-
item.fulltextWith Fulltext-
crisitem.author.dept04.05. Department of Pyhsics-
Appears in Collections:Physics / Fizik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
2607.pdfMakale758.11 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

44
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

33
checked on Mar 30, 2024

Page view(s)

226
checked on Apr 22, 2024

Download(s)

150
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.