Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3259
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorEroğlu, Ahmet Emin-
dc.contributor.authorErdem, Arzu-
dc.date.accessioned2014-07-22T13:51:12Z-
dc.date.available2014-07-22T13:51:12Z-
dc.date.issued2005-
dc.identifier.urihttp://hdl.handle.net/11147/3259-
dc.descriptionThesis (Master)--İzmir Institute of Technology, Chemistry, İzmir, 2005en_US
dc.descriptionIncludes bibliographical references (leaves: 48-51)en_US
dc.descriptionText in English; Abstract: Turkish and Englishen_US
dc.descriptionxi, 51 leavesen_US
dc.description.abstractA novel amalgamation/cold vapor atomic absorption spectrometric system was developed for the determination of Hg(II) concentration in water samples. In the next part, an amalgamation unit utilizing various Au-coated sorbents was constructed and tested in the determination of mercury. Among the new amalgamation materials suggested, gold-coated quartz wool was found to be the most efficient although gold sputter-coated carbon fiber gave also very promising results. Analytical performance of the CVAAS system in terms of sample volume, limit of detection, and without/with amalgamation was also investigated. It was observed that the mercury signal increased with increasing sample volume, as expected. On the other hand, provided that the absolute amount of Hg(II) was kept constant while changing the sample volume, use of amalgamation unit resulted in similar calibration sensitivities. With amalgamation, the linearity and the slope of the calibration plots were not dependant on the sample volume and this property is expected to offer an important advantage since it makes the volume adjustment unnecessary. The limit of detection was also improved with amalgamation. The highest improvement was obtained with 2.0 ml sample volume; the limit of detection was 3.5 times lower (3.5 times better) than that of without amalgamation when 5-times trapping was employed. The results demonstrated that the methodology can be applied to these types of samples directly or after amalgamation, depending on Hg(II) concentration.en_US
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lccQD181.H6 .E66 2005en
dc.subject.lcshMercuryen
dc.subject.lcshAmalgamationen
dc.subject.lcshAtomic absorption spectroscopyen
dc.titleUse of Different Gold Amalgamation Techniques in Mercury Determination by Cold Vapor Atomic Absorption Spectrometryen_US
dc.typeMaster Thesisen_US
dc.institutionauthorErdem, Arzu-
dc.departmentThesis (Master)--İzmir Institute of Technology, Chemistryen_US
dc.relation.publicationcategoryTezen_US
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityN/A-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairetypeMaster Thesis-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000354.pdfMasterThesis3.09 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

210
checked on Dec 23, 2024

Download(s)

80
checked on Dec 23, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.