dc.contributor.advisorTunçoku, Selim Sarpen
dc.contributor.authorYardım, Bülent-
dc.date.accessioned2014-07-22T13:51:21Z
dc.date.available2014-07-22T13:51:21Z
dc.date.issued2006en
dc.identifier.urihttp://hdl.handle.net/11147/3337
dc.descriptionThesis (Master)--Izmir Institute of Technology, Architectural Restoration, Izmir, 2006en
dc.descriptionIncludes bibliographical references (leaves: 66-69)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionxiii, 74 leavesen
dc.description.abstractThe study involves the examination of the dampness problems of a historic house, Nebahat Tabak House in Basmane District in zmir. The cause of dampness problems of the house was due to the rain penetration at the ground and first floors since the roof was damaged. In the basement however, dampness was felt but the cause was not so obvious. Therefore, the investigation was concentrated in the basement. Moisture contents and the temperature of the wall surfaces were determined by non-destructive techniques; by electrical conductivity measurements and infrared thermography. The results were evaluated in the light of physical properties, moisture and soluble salt contents of the materials, outdoor and indoor climatic conditions, the layout of the site and architectural features of the building.The results of the study revealed that most of the moisture was concentrated at the lower parts of the walls indicating rising damp. In addition to rising damp the faulty details detected at the intersection line of the terraces of the neighbor buildings, basement windows and the street also produce rain water leaks in addition to insufficient ventilation conditions in the basement.Condensation was not detected during the survey times which were usually noontimes. However, some cool zones having the risk of condensation at mornings and night time were observed.In the light of these findings, some alternative solutions for the faulty details have been proposed.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.publisherIzmir Institute of Technologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lccTH9031 .Y27 2006en
dc.subject.lcshDampness in buildingsen
dc.subject.lcshDampness in buildings--Preventionen
dc.subject.lcshHumidity--Controlen
dc.titleExamination of dampness problems of a historic houseen_US
dc.typeMaster Thesisen_US
dc.institutionauthorYardım, Bülent-
dc.departmentThesis (Master)--İzmir Institute of Technology, Conservation and Restoration of Cultural Heritageen_US
dc.relation.publicationcategoryTezen_US
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
item.languageiso639-1en-
item.fulltextWith Fulltext-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000539.pdfMasterThesis98.28 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

44
checked on Apr 22, 2024

Download(s)

16
checked on Apr 22, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.