Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3607
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBaşaran, Tahsinen
dc.contributor.authorAkdemir, Manolya-
dc.date.accessioned2014-07-22T13:51:56Z-
dc.date.available2014-07-22T13:51:56Z-
dc.date.issued2013en
dc.identifier.urihttp://hdl.handle.net/11147/3607-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2013en
dc.descriptionIncludes bibliographical references (leaves: 97-99)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionxii, 99 leavesen
dc.description.abstractPrimary objective of this thesis is to find out energy level of an existing building and investigate the opportunities in order to improve its energy level by retrofitting the envelope and using exergy analysis methods on alternative HVAC systems. To arrive at the objective, an existing building, Izmir Institute of Technology (IZTECH), Faculty of Architecture Block C, has been used as the case study. This building cannot comply with TS-825 standards (Turkish Standard Assessment) and energy efficiency parameters due to the building components and HVAC systems. According to the recorded outdoor climatic conditions, the building was modeled and simulated; and the retrofitting was tried in EDSL-TAS energy simulation software package. Simultaneously, exergy analyses for the situations before and after refurbishments were employed. Different from the most studies in the literature, this thesis carries out the exergy analyses using the dynamic data instead of the steady state ones. By the evaluation of these analyses together, energy level and the climatic comfort of the building have been seriously increased and the building’s loads have been decreased with ratio of 69.42% for heating system and 34.4% for cooling system after retrofitting. In exergy calculations, exergy efficiency of the system ranges between 2-14% with existing HVAC applications, 4-18% with Air Source Heat Pump (ASHP) and 8-21% with Ground Source Heat Pump (GSHP).en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lcshBuildings--Energy conservationen
dc.subject.lcshExergyen
dc.titleDynamic energy and exergy analysis of an existing building in IZTECHen_US
dc.typeMaster Thesisen_US
dc.institutionauthorAkdemir, Manolya-
dc.departmentThesis (Master)--İzmir Institute of Technology, Energy Systems Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
item.languageiso639-1en-
item.fulltextWith Fulltext-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
10011084.pdfMasterThesis7.93 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

166
checked on Apr 22, 2024

Download(s)

104
checked on Apr 22, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.