Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3988
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMobedi, Moghtadaen
dc.contributor.authorAnıl, Orkun Baki-
dc.date.accessioned2014-07-22T13:52:52Z-
dc.date.available2014-07-22T13:52:52Z-
dc.date.issued2008en
dc.identifier.urihttp://hdl.handle.net/11147/3988-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2008en
dc.descriptionIncludes bibliographical references (leaves: 127-131)en
dc.descriptionText in Englis; Abstract : Turkish and Englishen
dc.descriptionxiv, 131 leavesen
dc.description.abstractThere are various sterile spaces in hospitals which are highly at risk in terms of infection. HVAC systems play an important role on the infection risk in sterile spaces.HVAC systems for sterile spaces focus on number of particles, number and types of microorganisms, pressure difference between the sterile and its neighboring spaces, supply air velocity and air distribution in addition to the comfort parameters which are temperature, relative humidity and fresh air rate. Therefore, the design of HVAC systems for sterile spaces is more difficult and complicated compared to the comfort applications.This study firstly reviews the design parameters of HVAC systems of sterile spaces in hospitals. A literature survey is conducted about the effects of the design parameters on infection transmission in sterile spaces. Also a literature survey on various standards and design guidelines for HVAC design parameters of sterile spaces used by different countries is performed. Secondly, an experimental study was conducted in an operating room to reveal the system performance during operation.The reviewed standards and guidelines are compared via tables. The weak and strong points of the reviewed references are noted. Despite well known effects of HVAC systems on infection transmission, significant differences among standards and guidelines are observed. Based on the obtained experimental results, considerable differences of design parameters between .in operation. and .at rest. states were observed.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lccRA969.4 A612 2008en
dc.subject.lcshHospital buildings--Heating and ventilationen
dc.subject.lcshHospital buildings--Air conditioningen
dc.titleA research on design of heating, ventilation and air conditioning of hygienic spaces in hospitalsen_US
dc.typeMaster Thesisen_US
dc.institutionauthorAnıl, Orkun Baki-
dc.departmentThesis (Master)--İzmir Institute of Technology, Mechanical Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeMaster Thesis-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000752.pdfMasterThesis4.32 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

92
checked on Apr 15, 2024

Download(s)

74
checked on Apr 15, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.