Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/3988
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Mobedi, Moghtada | en |
dc.contributor.author | Anıl, Orkun Baki | - |
dc.date.accessioned | 2014-07-22T13:52:52Z | - |
dc.date.available | 2014-07-22T13:52:52Z | - |
dc.date.issued | 2008 | en |
dc.identifier.uri | http://hdl.handle.net/11147/3988 | - |
dc.description | Thesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2008 | en |
dc.description | Includes bibliographical references (leaves: 127-131) | en |
dc.description | Text in Englis; Abstract : Turkish and English | en |
dc.description | xiv, 131 leaves | en |
dc.description.abstract | There are various sterile spaces in hospitals which are highly at risk in terms of infection. HVAC systems play an important role on the infection risk in sterile spaces.HVAC systems for sterile spaces focus on number of particles, number and types of microorganisms, pressure difference between the sterile and its neighboring spaces, supply air velocity and air distribution in addition to the comfort parameters which are temperature, relative humidity and fresh air rate. Therefore, the design of HVAC systems for sterile spaces is more difficult and complicated compared to the comfort applications.This study firstly reviews the design parameters of HVAC systems of sterile spaces in hospitals. A literature survey is conducted about the effects of the design parameters on infection transmission in sterile spaces. Also a literature survey on various standards and design guidelines for HVAC design parameters of sterile spaces used by different countries is performed. Secondly, an experimental study was conducted in an operating room to reveal the system performance during operation.The reviewed standards and guidelines are compared via tables. The weak and strong points of the reviewed references are noted. Despite well known effects of HVAC systems on infection transmission, significant differences among standards and guidelines are observed. Based on the obtained experimental results, considerable differences of design parameters between .in operation. and .at rest. states were observed. | en |
dc.language.iso | en | en_US |
dc.publisher | Izmir Institute of Technology | en |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject.lcc | RA969.4 A612 2008 | en |
dc.subject.lcsh | Hospital buildings--Heating and ventilation | en |
dc.subject.lcsh | Hospital buildings--Air conditioning | en |
dc.title | A research on design of heating, ventilation and air conditioning of hygienic spaces in hospitals | en_US |
dc.type | Master Thesis | en_US |
dc.institutionauthor | Anıl, Orkun Baki | - |
dc.department | Thesis (Master)--İzmir Institute of Technology, Mechanical Engineering | en_US |
dc.relation.publicationcategory | Tez | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
item.openairetype | Master Thesis | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
Appears in Collections: | Master Degree / Yüksek Lisans Tezleri |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
T000752.pdf | MasterThesis | 4.32 MB | Adobe PDF | ![]() View/Open |
CORE Recommender
Page view(s)
22
checked on Nov 27, 2023
Download(s)
4
checked on Nov 27, 2023
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.