Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/4048
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Gökçen Akkurt, Gülden | en |
dc.contributor.author | Yaman, Mustafa Can | - |
dc.date.accessioned | 2014-07-22T13:53:04Z | - |
dc.date.available | 2014-07-22T13:53:04Z | - |
dc.date.issued | 2009 | en |
dc.identifier.uri | http://hdl.handle.net/11147/4048 | - |
dc.description | Thesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2009 | en |
dc.description | Includes bibliographical references (leaves: 79-83) | en |
dc.description | Text in English; Abstract: Turkish and English | en |
dc.description | xiii, 83 leaves | en |
dc.description.abstract | Energy performance of the buildings can be evaluated by measuring energy consumptions or performing simple or detailed simulation methods. In this study, IZTECH Administrative Building which is a university building, is selected as case study and energy audit is performed to evaluate energy performance of the building. Indoor conditions are recorded with dataloggers and outdoor climatic data is taken from IZTECH Meteorological Station. Fuel consumption is tracked by two flowmeters and electricity consumption is measured with three power analyzer connected to heating, cooling and lighting and general use electricity meters. Energy consumption of the building is simulated by three different methods which are TS 825 (static), CIBSE Admittance (simple dynamic) and ASHRAE Heat Balance (full dynamic) methods. Sensitivity of these methods is tested by comparing energy consumption measurements and simulations and performance improving measures are proposed. Also a hypothetical no-HVAC case is simulated. ASHRAE Heat Balance Method is determined as the most accurate model compared to measurement results and performance improving measures are simulated with this method, reduction in energy consumption and greenhouse gas emissions are observed. | en |
dc.language.iso | en | en_US |
dc.publisher | Izmir Institute of Technology | en |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject.lcc | TJ163.3 .Y19 2009 | en |
dc.subject.lcsh | Energy consumption--Analysis | en |
dc.subject.lcsh | Energy conservation--Research | en |
dc.subject.lcsh | Building Energy conservation | en |
dc.title | Energy efficiency in a university building: Energy performance assessment of IZTECH administrative building | en_US |
dc.type | Master Thesis | en_US |
dc.institutionauthor | Yaman, Mustafa Can | - |
dc.department | Thesis (Master)--İzmir Institute of Technology, Energy Systems Engineering | en_US |
dc.relation.publicationcategory | Tez | en_US |
item.languageiso639-1 | en | - |
item.fulltext | With Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | Master Thesis | - |
item.grantfulltext | open | - |
item.cerifentitytype | Publications | - |
Appears in Collections: | Master Degree / Yüksek Lisans Tezleri |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
T000815.pdf | MasterThesis | 2.68 MB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
132
checked on Jul 22, 2024
Download(s)
80
checked on Jul 22, 2024
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.