Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/4066
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorElçi, Şebnemen
dc.contributor.authorAydın, Ramazan-
dc.date.accessioned2014-07-22T13:53:06Z-
dc.date.available2014-07-22T13:53:06Z-
dc.date.issued2009en
dc.identifier.urihttp://hdl.handle.net/11147/4066-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Civil Engineering, Izmir, 2009en
dc.descriptionIncludes bibliographical references (leaves: 64-68)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionix, 71 leavesen
dc.description.abstractAcoustic Doppler current meters (ADCP, ADP, and ADV) can provide information about the suspended sediment concentration (SSC) in the water; although, they are designed for flow velocity measurements. Contrary to conventional samplers, those are labor intensive for measuring SSC, when an acoustic instrument is calibrated for a water system; no additional sensor is needed to measure SSC, enabling the researchers to measure velocity and concentration simultaneously which is required for most sediment transport studies. Recently, the acoustic instruments are investigated in different studies where signal to noise ratio (SNR) and SSC were related using different formulations. However, these studies were limited to single study site where neither the effect of particle size nor the effect of temperature was investigated. In the scope of this study, different parameters that affect the ADV.s performance prediction of SSC were investigated. In order to investigate the reliability of ADV in different environments, SSC measurements were made in different streams. Soil samples were collected from all measuring stations and particle size analysis was conducted. The multivariate data analysis was applied to the measurements to derive a relation formula between SNR and SSC. Multivariate analysis indicated that reported SSC values depended on at least three parameters; water temperature, mean diameter of the soil, and shape of the particle size distribution curve. Also, effect of high SSC conditions on ADV performance was investigated during and after rain events. Results indicated that ADV was not capable of measuring SSC when a limit concentration (SSC>400 mg/l) was exceeded.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lccTC175. A975 2009en
dc.subject.lcshWater current metersen
dc.subject.lcshSuspendend sedimentsen
dc.subject.lcshSediment transporten
dc.titleEstimation of suspendent sediment concentration using acoustic methodsen_US
dc.typeMaster Thesisen_US
dc.institutionauthorAydın, Ramazan-
dc.departmentThesis (Master)--İzmir Institute of Technology, Civil Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairetypeMaster Thesis-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000173.pdfMasterThesis2.32 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

60
checked on Apr 15, 2024

Download(s)

70
checked on Apr 15, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.