Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/4181
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSaatci, Selçuk
dc.contributor.authorArsan, Yonca-
dc.date.accessioned2014-11-18T11:38:28Z
dc.date.available2014-11-18T11:38:28Z
dc.date.issued2014
dc.identifier.urihttp://hdl.handle.net/11147/4181
dc.descriptionThesis (Master)--Izmir Institute of Technology, Civil Engineering, Izmir, 2014en_US
dc.descriptionIncludes bibliographical references (leaves: 98-99)en_US
dc.descriptionText in English; Abstract: Turkish and Englishen_US
dc.descriptionxii, 101 leavesen_US
dc.description.abstractDesign of reinforced concrete (RC) members against impact loads is required for many structures such as industrial facilities, military protective structures, and infrastructures. This study presents experimental investigation for strengthening RC slabs under impact loads using shear reinforcement. Slabs were strengthened against punching shear with two methods: using shear studs as shear reinforcement and using steel fiber reinforced concrete (SFRC) instead of plain concrete. Eight RC slabs with dimensions of 2150x2150x150 mm were tested. Four of the specimens, two identical pairs, were cast with shear studs around the point of impact. Remaining four specimens, again two identical pairs, were cast with 1% steel fibers. Pairs in each group contained two different levels of longitudinal reinforcement. For each pair, one specimen was tested under static loading, whereas its identical twin was tested under impact loads. Specimens were tested with a test setup that provides simply supported conditions. Support loads, displacements, accelerations, and strains on bars were measured during the tests. The study revealed that using shear studs and SFRC prevents brittle punching shear failure for both static and impact loading. Specimens with steel fibers reached the highest load carrying capacity for static test while specimens with shear reinforcement carried a smaller load for large deformations. Specimens with SFRC displayed a close to static behavior under impact loading, influenced only slightly by inertial forces due to impact. Specimens with shear studs were largely influenced by inertial forces and scabbing occurred at some areas. Specimens with steel fibers endured more impacts compared to control specimens and specimens with shear studs due to their higher energy dissipating capabilities.en_US
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectReinforced concreteen_US
dc.subjectSteel fibersen_US
dc.subject.lcshReinforced concrete--Testingen_US
dc.titleEffects of shear reinforcement on the impact behavior of reinforced concrete slabsen_US
dc.title.alternativeBetonarme döşemelerde kayma donatısının darbe davranışı üzerine etkilerien_US
dc.typeMaster Thesisen_US
dc.authoridTR115916en_US
dc.institutionauthorArsan, Yonca-
dc.departmentThesis (Master)--İzmir Institute of Technology, Civil Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
item.languageiso639-1en-
item.fulltextWith Fulltext-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
10013101.pdfMasterThesis7.84 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

132
checked on Apr 22, 2024

Download(s)

84
checked on Apr 22, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.