Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/4231
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSaygın, Nicel-
dc.contributor.authorMert, Yelda-
dc.date.accessioned2014-12-04T11:52:50Z-
dc.date.available2014-12-04T11:52:50Z-
dc.date.issued2014-03-
dc.identifier.urihttp://hdl.handle.net/11147/4231-
dc.descriptionThesis (Doctoral)--Izmir Institute of Technology, City and Regional Planning, Izmir, 2014en_US
dc.descriptionIncludes bibliographical references (leaves: 119-125)en_US
dc.descriptionText in English; Abstract: Turkish and Englishen_US
dc.descriptionFull text release delayed at author's request until 2017.04.03en_US
dc.description.abstractThis dissertation introduces the exergy analysis method into urban planning field in order to find out the amount of energy that can be conserved in a building block when energy efficient design is applied. Two hypotheses are developed here: 1. Exergy analysis is a suitable tool for the built environment, and 2. Energy efficient design parameters provide energy saving in the built environment. A case study approach is undertaken in order to test the hypotheses stated above. To do this, first, the energy efficient design parameters have been derived from the literature and design alternatives are developed accordingly; second, data has been gathered from the case area for the exergy calculations; third, exergy analysis of existing building blocks and proposed design alternatives are carried out, and finally, the amount of decrease in the exergy loss due to energy efficient design is found out. The findings in this study show that the exergy efficiency of the existing building blocks is nearly 2 %, while the proposed design alternatives are nearly 10-11 %. The overall exergy loads of the alternative plans are found as 166.3W, 225.1W, 142.5W, 137.8W and 184.8W respectively for winter and 105.4W, 140.0W, 89.9W, 86.3W and 125.3W respectively for summer on a housing unit basis. These results are much better when compared to the existing situation per housing unit which is 1079W (winter) and 1173W (summer). The best alternative energy efficient planning and design brings 1631 W (winter) and 2810W (summer) of exergy saving that corresponds to 799 TL/year and 978 kg/year reduction in CO2 greenhouse gases emission per housing unit. This data shows that the expected results and are in harmony with the literature. As a result, the suitability and importance of the exergy analysis on the built environment is proved by revealing the energy conservation and sustainable use of energy through using energy efficient design parameters.en_US
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCity planningen_US
dc.subjectUrban planningen_US
dc.subjectEnergy efficient planningen_US
dc.titleApplication of exergy analysis method to energy efficient building block designen_US
dc.title.alternativeEkserji analizi metodunun enerji etkin yapı adası tasarımına uygulanmasıen_US
dc.typeDoctoral Thesisen_US
dc.departmentThesis (Doctoral)--İzmir Institute of Technology, City and Regional Planningen_US
dc.relation.publicationcategoryTezen_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairetypeDoctoral Thesis-
Appears in Collections:Phd Degree / Doktora
Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection
Files in This Item:
File Description SizeFormat 
10013222.pdfDoctoralThesis5.35 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

132
checked on Apr 15, 2024

Download(s)

122
checked on Apr 15, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.