Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/4624
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÖzerdem, Barış-
dc.date.accessioned2016-05-10T11:40:55Z
dc.date.available2016-05-10T11:40:55Z
dc.date.issued2002
dc.identifier.citationÖzerdem, B. (2002). Tensile adhesion of type I collagen to titanium alloy and calcium phosphate coated surfaces with different roughness values. Bio-Medical Materials and Engineering, 12(4), 347-352.en_US
dc.identifier.issn0959-2989
dc.identifier.issn0959-2989-
dc.identifier.urihttp://hdl.handle.net/11147/4624
dc.description.abstractThe purpose of total joint arthroplasty is to reduce pain and restore function. Its success depends on the formation of a new bone that stabilizes the prosthesis. The proposed solution for this important problem is to have bio-coated implant surfaces which are more conductive to bone growth. Additionally, collagen has long been used as a matrix for medical applications, because of its biocompatibility and adaptability. In this study, a test method for measuring the tensile adhesion strength of collagen to titanium alloy and calcium phosphate coated surfaces with different roughness values was developed, in order to evaluate how well the collagen adheres to the metallic and bio-coated surfaces. A precision motion system was used to stretch gels that were adherent to the plate surfaces. The tests were done in DMEM solution. The adhesive strength between the collagen gel and plate was significantly higher for calcium phosphate coated surfaces. Adhesive strength was highest in the sample with the highest roughness value.en_US
dc.language.isoenen_US
dc.publisherIOS Pressen_US
dc.relation.ispartofBio-Medical Materials and Engineeringen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdhesionen_US
dc.subjectCalcium phosphateen_US
dc.subjectSurface roughnessen_US
dc.subjectTensile strengthen_US
dc.subjectTitanium alloyen_US
dc.titleTensile adhesion of type I collagen to titanium alloy and calcium phosphate coated surfaces with different roughness valuesen_US
dc.typeArticleen_US
dc.institutionauthorÖzerdem, Barış-
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.volume12en_US
dc.identifier.issue4en_US
dc.identifier.startpage347en_US
dc.identifier.endpage352en_US
dc.identifier.wosWOS:000180811900003en_US
dc.identifier.scopus2-s2.0-0036947461en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.pmid12652029en_US
dc.identifier.wosqualityQ4-
dc.identifier.scopusqualityQ1-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.grantfulltextopen-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
4624.pdfMakale91.14 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Mar 22, 2024

WEB OF SCIENCETM
Citations

3
checked on Mar 27, 2024

Page view(s)

100
checked on Mar 25, 2024

Download(s)

38
checked on Mar 25, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.