Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/7563
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYücel, Müge-
dc.contributor.authorAkın, Osman-
dc.contributor.authorÇayören, Mehmet-
dc.contributor.authorAkduman, İbrahim-
dc.contributor.authorPalaniappan, Alagappan-
dc.contributor.authorLiedberg, Bo-
dc.contributor.authorHızal, Gürkan-
dc.contributor.authorİnci, Fatih-
dc.contributor.authorYıldız, Ümit Hakan-
dc.date.accessioned2020-01-07T06:59:39Z-
dc.date.available2020-01-07T06:59:39Z-
dc.date.issued2018-04en_US
dc.identifier.citationYücel, M., Akın, O., Çayören, M., Akduman, İ., Palaniappan, A., Liedberg, B., Hızal, G., İnci, F., and Yıldız, Ü. H. (2018). Hand-Held volatilome analyzer based on elastically deformable nanofibers. Analytical Chemistry, 90(8), 5122-5129. doi:10.1021/acs.analchem.7b05187en_US
dc.identifier.issn0003-2700-
dc.identifier.issn0003-2700-
dc.identifier.issn1520-6882-
dc.identifier.urihttps://doi.org/10.1021/acs.analchem.7b05187-
dc.identifier.urihttps://hdl.handle.net/11147/7563-
dc.description.abstractThis study reports on a hand-held volatilome analyzer for selective determination of clinically relevant biomarkers in exhaled breath. The sensing platform is based on electrospun polymer nanofiber-multiwalled carbon nanotube (MWCNT) sensing microchannels. Polymer nanofibers of poly(vinylidene fluoride) (PVDF), polystyrene (PS), and poly(methyl methacrylate) (PMMA) incorporated with MWCNT exhibits a stable response to interferences of humidity and CO2 and provides selective deformations upon exposure of exhaled breath target volatilomes acetone and toluene, exhibiting correlation to diabetes and lung cancer, respectively. The sensing microchannels "P1" (PVDF-MWCNT), "P2" (PS-MWCNT), and "P3" (PMMA-MWCNT) are integrated with a microfluidic cartridge (μ-card) that facilitates collection and concentration of exhaled breath. The volatilome analyzer consists of a conductivity monitoring unit, signal conditioning circuitries and a low energy display module. A combinatorial operation algorithm was developed for analyzing normalized resistivity changes of the sensing microchannels upon exposure to breath in the concentration ranges between 35 ppb and 3.0 ppm for acetone and 1 ppb and 10 ppm for toluene. Subsequently, responses of volatilomes from individuals in the different risk groups of diabetes were evaluated for validation of the proposed methodology. We foresee that proposed methodology provides an avenue for rapid detection of volatilomes thereby enabling point of care diagnosis in high-risk group individuals.en_US
dc.language.isoenen_US
dc.publisherAmerican Chemical Societyen_US
dc.relation.ispartofAnalytical Chemistryen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNanofibersen_US
dc.subjectMultiwalled carbon nanotubesen_US
dc.subjectPoly(methyl methacrylate)en_US
dc.subjectPoly (vinylidene fluoride)en_US
dc.subjectMicrochannelsen_US
dc.titleHand-Held volatilome analyzer based on elastically deformable nanofibersen_US
dc.typeArticleen_US
dc.authorid0000-0002-6922-4454en_US
dc.institutionauthorYücel, Müge-
dc.institutionauthorYıldız, Ümit Hakan-
dc.departmentİzmir Institute of Technology. Chemistryen_US
dc.departmentİzmir Institute of Technology. Bioengineeringen_US
dc.identifier.volume90en_US
dc.identifier.issue8en_US
dc.identifier.startpage5122en_US
dc.identifier.endpage5129en_US
dc.identifier.wosWOS:000430512200028en_US
dc.identifier.scopus2-s2.0-85045666844en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1021/acs.analchem.7b05187-
dc.identifier.pmid29557164en_US
dc.relation.doi10.1021/acs.analchem.7b05187en_US
dc.coverage.doi10.1021/acs.analchem.7b05187en_US
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.languageiso639-1en-
item.fulltextWith Fulltext-
crisitem.author.dept04.01. Department of Chemistry-
Appears in Collections:Bioengineering / Biyomühendislik
Chemistry / Kimya
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
acs.analchem.7b05187.pdfMakale (Article)5.96 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

16
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

16
checked on Mar 27, 2024

Page view(s)

2,232
checked on Apr 22, 2024

Download(s)

330
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.