Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/8768
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKhachatryan, V.-
dc.contributor.authorSirunyan, A. M.-
dc.contributor.authorTumasyan, A.-
dc.contributor.authorAdam, W.-
dc.contributor.authorAsilar, E.-
dc.contributor.authorBergauer, T.-
dc.contributor.authorKarapınar, Güler-
dc.contributor.authorCMS Collaboration-
dc.date.accessioned2020-07-18T08:31:24Z-
dc.date.available2020-07-18T08:31:24Z-
dc.date.issued2017-
dc.identifier.issn1748-0221-
dc.identifier.urihttps://doi.org/10.1088/1748-0221/12/01/P01020-
dc.identifier.urihttps://hdl.handle.net/11147/8768-
dc.descriptionWOS: 000395769600020en_US
dc.description.abstractThis paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton (heavy ion) collisions. The first level of the trigger is implemented in hardware, and selects events containing detector signals consistent with an electron, photon, muon, tau lepton, jet, or missing transverse energy. A programmable menu of up to 128 object-based algorithms is used to select events for subsequent processing. The trigger thresholds are adjusted to the LHC instantaneous luminosity during data taking in order to restrict the output rate to 100 kHz, the upper limit imposed by the CMS readout electronics. The second level, implemented in software, further refines the purity of the output stream, selecting an average rate of 400 Hz for offline event storage. The objectives, strategy and performance of the trigger system during the LHC Run 1 are described.en_US
dc.language.isoenen_US
dc.publisherIOP Publishing Ltd.en_US
dc.relation.ispartofJournal of Instrumentationen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTrigger concepts and systems (hardware and software)en_US
dc.subjectTrigger detectorsen_US
dc.subjectData acquisition circuitsen_US
dc.titleThe CMS trigger systemen_US
dc.typeArticleen_US
dc.institutionauthorKarapınar, Güler-
dc.departmentİzmir Institute of Technology. Mathematicsen_US
dc.identifier.volume12en_US
dc.identifier.wosWOS:000395769600020en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1088/1748-0221/12/01/P01020-
dc.relation.doi10.1088/1748-0221/12/01/P01020en_US
dc.coverage.doi10.1088/1748-0221/12/01/P01020en_US
dc.identifier.wosqualityQ3-
dc.identifier.scopusqualityQ2-
dc.identifier.wosqualityttpTop10%en_US
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.languageiso639-1en-
item.fulltextNo Fulltext-
crisitem.author.dept01. Izmir Institute of Technology-
Appears in Collections:Rectorate / Rektörlük
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

430
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

528
checked on Mar 30, 2024

Page view(s)

164
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.