Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/1991
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÖzdemir, Durmuştr
dc.contributor.authorDinç, Erdaltr
dc.date.accessioned2016-07-27T10:26:25Z-
dc.date.available2016-07-27T10:26:25Z-
dc.date.issued2005-02-
dc.identifier.citationÖzdemir, D., and Dinç, E. (2005). Determination of benazepril HCl and hydrochlorothiazide in pharmaceutical preparations using UV-visible spectrophotometry and genetic multivariate calibration method. Journal of Food and Drug Analysis,13(4), 301-311.en_US
dc.identifier.issn1021-9498-
dc.identifier.urihttp://hdl.handle.net/11147/1991-
dc.identifier.urihttps://doi.org/10.38212/2224-6614.2564-
dc.description.abstractSimultaneous determination of binary mixtures of benazepril and hydrochlorothiazide in pharmaceutical tablets using UV-visible spectrophotometry, classical least squares (CLS) and three genetic algorithms (GA) based multivariate calibration methods was demonstrated. The three genetic multivariate calibration methods are Genetic Classical Least Squares (GCLS), Genetic Inverse Least Squares (GILS) and Genetic Regression (GR). The sample data set contains the UV- spectra of 28 synthetic mixtures of benazepril (12∼36 μg/mL) and hydrochlorothiazide (10∼22 μg/mL) and 16 tablets containing both compounds. The spectra cover the range from 210 to 360 nm in 0.1 mn intervals. Several calibration models were built with the four methods. The root mean square error of calibration (RMSEC) and validation (RMSEV) for the synthetic data were in the range of 0.19 and 0.34 μg/mL for all the genetic algorithm based methods. The root mean square error of Prediction (RMSEP) values for the tablets were in the range of 0.04∼0.20 mg/tablets. A comparison of genetic algorithm selected wavelengths for each component was also included.en_US
dc.language.isoenen_US
dc.publisherTaiwan Food and Drug Administrationen_US
dc.relation.ispartofJournal of Food and Drug Analysisen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBenazepril plus hydrochlorothiazideen_US
dc.subjectDivitaben_US
dc.subjectGenetic algorithmsen_US
dc.subjectGenetic regressionen_US
dc.subjectMultivariate calibrationen_US
dc.titleDetermination of benazepril HCl and hydrochlorothiazide in pharmaceutical preparations using UV-visible spectrophotometry and genetic multivariate calibration methoden_US
dc.typeArticleen_US
dc.institutionauthorÖzdemir, Durmuş-
dc.departmentİzmir Institute of Technology. Chemistryen_US
dc.identifier.volume13en_US
dc.identifier.issue4en_US
dc.identifier.startpage301en_US
dc.identifier.endpage311en_US
dc.identifier.wosWOS:000234330700002en_US
dc.identifier.scopus2-s2.0-33244485075en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr
dc.identifier.doi10.38212/2224-6614.2564-
dc.identifier.wosqualityQ3-
dc.identifier.scopusqualityQ2-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
crisitem.author.dept04.01. Department of Chemistry-
Appears in Collections:Chemistry / Kimya
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
1991.pdfMakale539.3 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

10
checked on Apr 14, 2023

WEB OF SCIENCETM
Citations

3
checked on Apr 26, 2024

Page view(s)

692
checked on Apr 29, 2024

Download(s)

274
checked on Apr 29, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.