Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3813
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorÖzkol, Ünveren
dc.contributor.authorCeyhan Zeren, Fatma Tuba-
dc.date.accessioned2014-07-22T13:52:25Z-
dc.date.available2014-07-22T13:52:25Z-
dc.date.issued2010en
dc.identifier.urihttp://hdl.handle.net/11147/3813-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2010en
dc.descriptionIncludes bibliographical references (leaves: 50-51)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionx, 55 leavesen
dc.description.abstractSpace cooling and heating are needed throughout the year for commercial buildings and electricity use in these buildings accounts for about one-third of the total energy consumption in Turkey. In this study, Adnan Menderes International Airport (ADM) located in Izmir is simulated with EnergyPlus software which is a new generation building energy analysis tool. The simulation model is constructed first with Design Builder and than the measured data are used to compare the model. EnergyPlus simulations are used in this thesis to help understanding more about the ADM.s dynamics and evaluate various strategies such as different orientation and heating, cooling, ventilation and air conditioning (HVAC) system. According to simulation and different HVAC system results; cooling electricity consumption increases 2.8 times in each month. According to simulation and east orientation results, heat gains decrease between 2% and 11% in winter, autumn and spring months and increase between 3% and 14% in summer months. Measured data of ADM building showed that HVAC system had constituted almost 80% of the total energy consumption, according to the average data obtained in 2008. The difference between measured and simulation consumption values are greater more than 70%. According to simulation results, also there is 2.4 times more electricity consumption on 18 August when compared to 11 January. Finally, analysis showed that ADM building requires year-round cooling and very little heating.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lcshBuildings--Energy conservationen
dc.subject.lcshHeating and ventilating industryen
dc.subject.lcshEnergy conservation--Evaluationen
dc.titleEnergy performance analysis of Adnan Menderes International Airport (ADM)en_US
dc.typeMaster Thesisen_US
dc.institutionauthorCeyhan Zeren, Fatma Tuba-
dc.departmentThesis (Master)--İzmir Institute of Technology, Energy Systems Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.openairetypeMaster Thesis-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.grantfulltextopen-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000825.pdfMasterThesis4.73 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

180
checked on Mar 25, 2024

Download(s)

192
checked on Mar 25, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.