Bilgilendirme: Sürüm Güncellemesi ve versiyon yükseltmesi nedeniyle, geçici süreyle zaman zaman kesintiler yaşanabilir ve veri içeriğinde değişkenlikler gözlemlenebilir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Impedimetric Detection of Pathogenic Bacteria With Bacteriophages Using Gold Nanorod Deposited Graphite Electrodes

Loading...
Thumbnail Image

Date

2016

Journal Title

Journal ISSN

Volume Title

Publisher

Royal Society of Chemistry

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Journal Issue

Abstract

Electrochemical impedance spectroscopy (EIS) is applied for the detection of bacteria using bacteriophages as a bioprobe together with gold nanorods (GNRs). Escherichia coli-E. coli K12 was used as a model target bacteria and also for the propagation of its specific T4-phages. Gold nanorods (GNRs) were synthesized via a two-step protocol and characterized using different techniques. EIS measurements were conducted in an electrochemical cell consisting of a three electrode system. Single-use pencil graphite electrodes (PGE) were modified by the physical adsorption of GNRs to increase their interfacial conductivity and therefore sensitivity for impedimetric measurements. Therefore, interfacial charge-transfer resistance values (Rct) sharply decreased after GNRs deposition. Phages were adsorbed on these electrodes via a simple incubation protocol at room temperature, which resulted in an increase in Rct values, which was concluded to be as a result of nonconductive phage layers. These phage-carrying GNRs-PGEs were used for impedimetric detection of the target bacteria, E. coli. Significant increases at the Rct values were observed which were attributed to the insulation effects of the adsorbed bacterial layers. This increase was even more when the bacterial concentrations were higher. In the case of the non-target bacteria Staphylococcus aureus (S. aureus), conductivity noticeable decreases (due to nonspecific adsorption). However, in the case of E. coli, the Rct value increase is time dependent and reaches maximum in about 25-30 min, then decreases gradually as a result of bacterial lysis due to phage invasion on the electrode surfaces. In contrast, there were no time dependent changes with the non-target bacteria S. aureus (no infection and no lytic activity). It is concluded that the target bacteria could be detected using this very simple and inexpensive detection protocol with a minimum detection limit of 103 CFU mL-1 in approximately 100 μL bacterial suspension.

Description

Keywords

Graphite electrodes, Gold, Bacteriophages, Charge transfer, Escherichia coli, Nanoribbons, Bacteriophages

Turkish CoHE Thesis Center URL

Fields of Science

Citation

Moghtader, F., Çongur, G., Zareie, H. M., Erdem, A., and Pişkin, E. (2016). Impedimetric detection of pathogenic bacteria with bacteriophages using gold nanorod deposited graphite electrodes. RSC Advances, 6(100), 97832-97839. doi:10.1039/c6ra18884b

WoS Q

Q2

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
44

Source

RSC Advances

Volume

6

Issue

100

Start Page

97832

End Page

97839
SCOPUS™ Citations

45

checked on Sep 17, 2025

Web of Science™ Citations

42

checked on Sep 17, 2025

Page Views

455

checked on Sep 17, 2025

Downloads

448

checked on Sep 17, 2025

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.545

Sustainable Development Goals

SDG data is not available